Specification & Technical Parameters:

Model KCOC-3.7P KCOC-5P KCOC-6P KCOC-8P KCOC-10P KCOC-12P KCOC-15P
Cooling capacity (kcal/h) 8000 12000 15000 18000 25000 30000 40000
(W) 9300 14000 17400 20900 29000 35000 46500
Oil temperature range Temperature-fixed type: adjustable from 20 to 50; Room temperature-adjustable type: room temperature ± ΔT (ΔT = 1~3)
Usage conditions Environmental requirements 5~43, well-ventilated, free from dust and corrosive mists, protected from direct sunlight and rain, heat radiation, and vibration.
oil temperature 15~50
Oil types Hydraulic oil, lubricating oil
oil viscosity Cst 20~100
Main power supply V 3PH/AC380V±10%/50Hz
Oil-free pump input power kW 3.6 5.1 6.3 7.5 10 12 15
Oil pump input power kW 5.1 6.6 8.5 9.7 13 15 19
Input current for oil pump A 11 13.5 16 18 26 28 37
compressor input power kW 3.4 4.6 5.8 6.8 9.2 11.1 12.9
oil pump Input power kW 1.5 1.5 2.2 2.2 3 3 4
flow L/min 50 50 63 80 100 115 160
Interface dimensions (internal thread) inch G1″×1″ G1″×1″ G1¹/“×1¹/ G1¹/“×1¹/ G1¹/“×1¹/ G1¹/“×1¹/ G2″×2″
External pipe inner diameter mm DN25 DN25 DN32 DN32 DN40 DN40 DN50
External dimensions Width mm 700 700 800 800 880 930 970
thick mm 750 750 850 850 970 1050 1200
high mm 1300 1300 1420 1500 1650 1750 1880
weight kg 150 180 220 280 350 400 600
Fuel tank dimensions Width mm 700 700 800 800 / / /
thick mm 750 750 850 850 / / /
high mm 1550 1550 1670 1750 / / /
fuel tank capacity L 100 100 130 130 / / /
fuel tank weight kg 180 210 255 315 / / /
refrigerant R410A
Protective devices Refrigerant high/low voltage protection, overload/short circuit/delay protection, power phase loss/reverse phase protection.

Notes:

  • Cooling capacity refers to the cooling output under the conditions of an ambient temperature of 35℃, an inlet oil temperature of 40℃, and the use of 32# hydraulic oil;
  • This series of units includes two models: Fixed Temperature Type A and Room Temperature Adjustable Type B, for users to choose from;
  • This series of units includes three models: Without Pump and Without Oil Tank, With Pump but Without Oil Tank (Type P), and With Pump and With Oil Tank (Type PX), for selection only;
  • The lower limit temperature for both the Fixed Temperature Type and the Room Temperature Adjustable Type is 15℃;
  • During installation, a space of at least 80cm must be maintained at the air intake, and a space of at least 200cm must be maintained at the hot air exhaust outlet.